5_25_floppy_drives:teac_fd_55br
Differences
This shows you the differences between two versions of the page.
| Next revision | Previous revision | ||
| 5_25_floppy_drives:teac_fd_55br [2022/01/15 12:21] – created js | 5_25_floppy_drives:teac_fd_55br [2022/01/15 12:28] (current) – js | ||
|---|---|---|---|
| Line 20: | Line 20: | ||
| ====== TEAC FD-55BR ====== | ====== TEAC FD-55BR ====== | ||
| The FD-55BR is a 5.25" double sided double density floppy drive made by TEAC. It is part of their FD-55 series and was introduced in the beginning of the 1990s. | The FD-55BR is a 5.25" double sided double density floppy drive made by TEAC. It is part of their FD-55 series and was introduced in the beginning of the 1990s. | ||
| - | There are multiple variants that are listed below. All variants use metal belts to facilitate head movement and lock the disk with a lever. Head loading is either | + | There are multiple variants that are listed below. All variants use metal belts to facilitate head movement and lock the disk with a lever. Head loading is done with a solenoid. |
| The drive can read and write at double density and only read at single density. | The drive can read and write at double density and only read at single density. | ||
| Line 30: | Line 30: | ||
| The 101-U variant has a Black front bezel. | The 101-U variant has a Black front bezel. | ||
| - | It uses the [[# | + | It uses the [[# |
| === Pictures === | === Pictures === | ||
| | {{: | | {{: | ||
| Line 41: | Line 41: | ||
| {{pdfjs 100%, | {{pdfjs 100%, | ||
| ++++ | ++++ | ||
| + | ===== Common issues ===== | ||
| + | ==== Track Zero Misalignment ==== | ||
| + | When removing or swapping the control board the Track Zero alignment is lost and has to be realigned. | ||
| + | The Track Zero alignment is adjusted by loosening the control board screws and sliding it forward or backward. | ||
| + | If the board is to far back the head assembly will never reach the sensor and will hit the back end of travel. | ||
| + | In this case the floppy controller might try to reach zero multiple times, causing a fast repeating knocking noise. | ||
| + | |||
| + | The Track Zero alignment can be performed by following these steps: | ||
| + | - Loosen the control board screws so that it can slide back and forth with some resistance. | ||
| + | - Slide the control board all the way backward (towards the connectors). | ||
| + | - Repeat until Track Zero alignment is correct: | ||
| + | - Move the control board forward (towards the front bezel) by about 0.25mm. | ||
| + | - Try to read a disk or use KryoFlux track calibration mode ("dtc -v360 -i4 -c1"). | ||
| + | - If the disk reads fine or KryoFlux shows reading of track 0, then the Track Zero alignment should be OK. | ||
| + | - If the disk doesn' | ||
| + | - Stop the disk reading or KryoFlux track calibration mode. | ||
| + | - After reaching a good control board position it is advised to check the alignment multiple times to ensure that it is working all the time. | ||
| + | - Tighten the control board screws, make sure not to move the board while doing so. | ||
| + | |||
5_25_floppy_drives/teac_fd_55br.1642245718.txt.gz · Last modified: by js
